SDS2000X Series Super Phosphor Oscilloscopes

  • 70 MHz, 100 MHz, 200 MHz, 300 MHz models
  • Real-time sampling rate up to 2 GSa/s
  • New generation of SPO technology
  • Waveform capture rate up to 140,000 wfm/s (normal mode), and 500,000 wfm/s (sequence mode)
  • Supports 256-level intensity grading and color temperature display
  • Record length up to 140 Mpts
  • Digital trigger system

Product Overview

SIGLENT’s SDS2000X Series Super Phosphor Oscilloscopes are available in bandwidths of 70 MHz, 100 MHz, 200 MHz and 300 MHz, maximum sample rate of 2 GSa/s, and come with a maximum record length of 140 Mpts. The most commonly used functions can be accessed with its user-friendly one-button design.

The SDS2000X series employs a new generation of SPO technology. It has an innovative digital trigger system with high sensitivity and low jitter, and a maximum waveform capture rate of 140,000 wfm/s (normal mode), up to 500,000 wfm/s (sequence mode). It also employs the common 256-level intensity grading display function but also a color temperature display mode. The trigger system supports multiple powerful triggering modes including serial bus triggering, History waveform recording and sequence acquisition allow for extended waveform records to be captured, stored, and analyzed. An impressive array of measurement and math capabilities, options for a built-in 25 MHz arbitrary waveform generator, 16 digital channels (MSO), as well as serial decoding are also features of the SDS2000X.

Bandwidth Channels Real time
sampling rate
Capture rate Memory depth Price
SDS2304X 300 MHz 4 CH 2 GSa/s 140,000 wfm/s 140 Mpts $2,815 Buy Now
SDS2302X 300 MHz 2 CH 2 GSa/s 140,000 wfm/s 140 Mpts $2,199 Buy Now
SDS2204X 200 MHz 4 CH 2 GSa/s 140,000 wfm/s 140 Mpts $2,189 Buy Now
SDS2202X 200 MHz 2 CH 2 GSa/s 140,000 wfm/s 140 Mpts $1,595 Buy Now
SDS2104X 100 MHz 4 CH 2 GSa/s 140,000 wfm/s 140 Mpts $1,639 Buy Now
SDS2102X 100 MHz 2 CH 2 GSa/s 140,000 wfm/s 140 Mpts $1,129 Buy Now
SDS2074X 70 MHz 4 CH 2 GSa/s 140,000 wfm/s 140 Mpts $1,285 Buy Now
SDS2072X 70 MHz 2 CH 2 GSa/s 140,000 wfm/s 140 Mpts $885 Buy Now
Limited Time Offer

Buy More and Spend Less – Save 30% on Siglent’s SDS2000X Oscilloscopes. Learn More

Key Features

  • Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern and Video (HDTV supported)
  • Serial bus triggering and decoder, supports protocols IIC, SPI, UART, RS232, CAN and LIN (Optional)
  • Low background noise, supports 1 mV/div to 10 V/div voltage scales
  • 10 types of one-button shortcuts, including Auto Setup, Default, Cursors, Measure, Roll, History,
    Display/Persist, Clear Sweeps, Zoom and Print
  • Segmented acquisition (Sequence) mode divides the maximum record length into multiple segments
    (up to 80,000),according to trigger conditions set by the user. The resulting acquisition has a very small
    dead time segment.
  • History waveform record (History) function, the maximumr ecorded waveform length is 80,000 frames
  • Automatic measurement function on 37 parameters, supports statistics, Gating measurements, Math
    measurements, History measurements and Ref measurements
  • Math function (FFT, addition, subtraction, multiplication, division, integration, differential, square root)
  • High Speed hardware based Pass/ Fail function
  • 16 Digital channels (MSO option), Maximum waveform capture rate up to 500 MSa/s, Record length
    up to 140 Mpt/CH

I spent a long time researching various oscilloscopes. It got to be fairly evident that the Siglent line clearly gave the best performance per dollar invested of any of these instruments. Once I received the scope, I was delighted to find that my research had paid off. The scope is very easy to use and certainly meets all of its specifications.

Richard Melvilleon
August 31, 2016

Need more information? Call us now 877-515-5551

8-inch TFT-LCD display with 800 * 480 resolution. Most commonly used functions are accessible using 10 different one-button operation keys: Auto Setup, Default, Cursors, Measure, Roll, History, Display/Persist, Clear Sweeps, Zoom and Print. Supports auto detection of 10X probe with read-out port (200 MHz and 300 MHz versions only).

Product Characteristics

Waveform Capture Rate up to 500,000 wfm/s View more

Waveform Capture Rate up to 500,000 wfm/s

With a waveform capture rate of up to 500,000 wfm/s (sequence mode), the oscilloscope can easily capture the unusual or small probability events

Record Length of up to 140 Mpts View more

Record Length of up to 140 Mpts

Using hardware-based Zoom technique and a record length of up to 140 Mpts, users are able to use a higher sampling rate to capture more of the signal, and then quickly zoom in to focus on the area of interest

256-level Intensity Grading and Color Temperature Display View more

256-level Intensity Grading and Color Temperature Display

SPO display technology is the result of high refresh rate and multi-frame superimposition. In the unit of time, the higher the probability of a pixel waveform appears, the brighter the pixel.

256-level Intensity Grading and Color Temperature Display View more

256-level Intensity Grading and Color Temperature Display

The degree of warm or cool of color suggests the probability of the appearing of waveform. The warmer the color, the higher the probability.

Variety of Trigger Functions View more

Variety of Trigger Functions

Edge, Slope, Pulse, Video, Windows, Runt, Interval, Dropout, Pattern, IIC, SPI, UART/RS232, LIN and CAN

History Mode View more

History Mode

History function can record up to 80,000 frames of waveforms.

The recording is carried out automatically, so that the customer can play back the history waveforms at any time to observe unusual events, and locate the source quickly through the cursors or measurements.

Located on the keyboard Panel, this function is easily accessible

Sequence Mode View more

Sequence Mode

Segmented memory collection will store the waveform into multiple (up to 80,000) memory segments and each segment will store a triggered waveform, as well the dead time information. The dead time between segments can be as small as 2μs. All the segments can be played back using History function.

Comprehensive Statistical Functions View more

Comprehensive Statistical Functions

Parametric statistical functions to display 5 parameters for any set of measurements: current, mean, minimum value, maximum value, and standard deviation. The measurement count is also displayed. The maximum number of measurements that can be run and simultaneously analyzed statistically is five. Supports Gating measurements, Math measurement, History measurement and Ref measurement.

Advanced Math Function View more

Advanced Math Function

In addition to the traditional (+, -, X, /) operations, FFT, integration, differential, and square root operations are supported. The integration operation supports gating, which uses cursors to define the domain of integration.

Eres Mode View more

Eres Mode

Eres mode can improve the SNR effectively, without the dependence on the periodicity of signal and stable triggering

16 Digital Channels / MSO (Optional) View more

16 Digital Channels / MSO (Optional)

4 analog channels plus 16 digital channels enables users to acquire and trigger on the waveform then analyze  the pattern, simultaneously with one instrument.

Serial Bus Decoding Function (Optional) View more

Serial Bus Decoding Function (Optional)

Displays the decoding through the events list. Bus protocol information can be quickly and intuitively displayed in table form.

Built-in 25 MHz Function/Arbitrary Waveform Generator (Optional) View more

Built-in 25 MHz Function/Arbitrary Waveform Generator (Optional)

10 built-in waveforms plus 4 ARBs. The arbitrary waveforms can be accessed and edited by the EasyWave PC software

Standard Accessories

  • Power Cord

    Power cord designed for use with the instrument in the country of operation. Available separately. Power cord H05VV-F 3G0.75MM2-004; GB-line power line (L = 1.5m ± 20mm) three plugs; product suffix; 0.13 square; black (Ju Yu)

  • Quick Start

    Printed Quick Start Guide (English)

  • USB Cable

    Standard USB cable. Also available separately.


Optional Accessories

  • SRF5030T

    Three magnetic field near-field probes and one electric field near field probe; Frequency range: 30MHz ~ 3GHz; resolution 25mm; distinguished within 10cm range of the magnetic field; for EMI radiation interference and the intensity detector.

  • STB-3

    Oscilloscope Demonstration Board. Provides standard (Sine, Square), pulse (PWM, Burst), and serial (I2C, SPI, UART, LIN, and CAN) outputs.

  • Passive Probe

    PB470; PP510; PP215; PP430

  • Current Probe

    CP4020; CP4050; CP4070; CP4070A; CP5030; CP5030A; CP5150; CP5500

  • SRF5030

    Four magnetic field near-field probes; Frequency range: 30MHz ~ 3GHz; resolution 25mm; distinguished within 10cm range of the magnetic field; for EMI radiation interference and the intensity detector.

  • High Voltage Probe

    Bandwidth: 40MHz; Maximum input differential voltage DC:10KV; AC(rms):7KV(sine);AC(Vpp):20KV(Pulse); attenuation ratio1:1000; Accuracy:≤3%

  • High Voltage Differential Probe

    DPB5150, DPB5150A, DPB5700, DPB5700A, DPB4080

  • SP2030A

    10X attenuation, 12 pf, 10Mohm ±2% , DC-300MHz, < 600 V DC+Peak AC, operating temperature 0 ℃ -50 ℃

  • SDS2000-RMK

    Rackmount kit is designed for use with only one instrument. It is compatible with SDS2000 and SDS2000X series oscilloscopes.

  • Isolated channel optional accessories(ISFE)

    Add isolated inputs to your oscilloscope using passive probes. Enables floating ground differential signal analysis. Overview: The ISFE provides isolated input capabilities to any oscilloscope. Independently developed by SIGLENT, it is designed to measure signals that do not share earth ground with the oscilloscope. It is suitable for use with SIGLENT’s full range of oscilloscope products. … Continued

  • SDS-2000X-FG

    Activation license for the 25MHz Function/Arbitrary Waveform Generator

  • SDS-2000X-DC

    Activation license for the IIC, SPI, UART/RS232, CAN, LIN decoding package

  • SDS-2000X-PA (sw)

    Power analysis Software for the SDS2000X Oscilloscopes

  • DF2001A

    Power analysis deskew fixture for voltage and current probes (This option is only available on 4 channel units of SDS2000 and SDS2000X Series)

  • SDS-2000-LA(SW)

    Optional Activation license for the MSO option for SDS2000 oscilloscope​ – Note: The Logic Analyzer (MSO) option requires both the SPL1008 and the SDS-2000-LA

  • SPL2016

    Logic Probe for SDS2000X series , 16-channel, 500MSa/s

  • BAG-SCC

    Soft Carry Case for SDS1000CFL, SDS2000, SDS2000X, SDS1000X/X+, SSA3000X.

Support and Resources

Application Notes

Verify an open socket LAN connection using Telnet

Automating a test can dramatically increase the productivity, throughput, and accuracy of a process. Automating a setup involves connecting a computer to the test instrumentation using a standard communications bus like USB or LAN and then utilizing code entered via a software layer (like LabVIEW, .NET, Python, etc..) to sequence the specific instrument commands and … Continued

Verification of a working remote communications connection using NI – MAX

Automating a test can dramatically increase the productivity, throughput, and accuracy of a process. Automating a setup involves connecting a computer to the test instrumentation using a standard communications bus like USB or LAN and then utilizing code entered via a software layer (like LabVIEW, .NET, Python, etc..) to sequence the specific instrument commands and … Continued