SDS1000X/X+ Series Super Phosphor Oscilloscopes

  • 200 MHz, 100 MHz bandwidth models
  • Real-time sampling rate up to 1GSa/s
  • New generation of SPO technology
  • Waveform capture rate up to 60,000 wfm/s (normal mode), and 400,000 wfm/s(sequence mode)
  • Supports 256-level intensity grading and color display modes
  • Record length up to 14 Mpts
  • Digital trigger system

Product Overview

SIGLENT’s new SDS1000X/SDS1000X+ Series Super Phosphor Oscilloscopes are available in two bandwidths, 100 MHz and 200 MHz, have a sampling rate of 1 GSa/s and a standard record length of 14 Mpts. The most commonly used functions can be accessed with its user-friendly one-button design.

The SDS1000X/SDS1000X+ series employs a new generation of SPO technology. With its excellent signal fidelity, background noise is lower than similar products in the industry. It has a minimum vertical input range of 500 uV/div, an innovative digital trigger system with high sensitivity and low jitter, and a waveform capture rate of 60,000 frames/sec. It also employs not only the common 256-level intensity grading display function but also a color temperature display mode not found in other models in this class. Siglent’s new oscilloscopes offering supports multiple powerful triggering modes including serial bus triggering and decoding. History waveform recording and sequential triggering allow for extended waveform records to be captured, stored, and analyzed. SDS1000X+ adds an integrated 25 MHz arbitrary waveform generator (standard), option for 16 digital channels. The features and high-performance of the SDS1000X/SDS1000X+ oscilloscopes cannot be matched at any product at this price.

Bandwidth Channels Real time
sampling rate
Capture rate Memory depth Price
SDS1202X+ 200 MHz 2+EXT 1 GSa/s 60,000 wfm/s 14 Mpts $899 Buy Now
SDS1102X+ 100 MHz 2+EXT 1 GSa/s 60,000 wfm/s 14 Mpts $759 Buy Now
SDS1202X 200 MHz 2+EXT 1 GSa/s 60,000 wfm/s 14 Mpts $659 Buy Now
SDS1102X 100 MHz 2+EXT 1 GSa/s 60,000 wfm/s 14 Mpts $499 Buy Now
Limited Time Offer

Save 15% and Get Free Decode Option on SDS1000X/X+ for Limited Time!

Key Features

  • Intelligent trigger: Edge, Slope, Pulse Width, Window, Runt, Interval, Time out (Dropout),Pattern
  • Serial bus triggering and decode, supports protocols IIC, SPI, UART, RS232, CAN, LIN
  • Video triggers and supports HDTV
  • Low background noise, supports 500μV / div to 10V / div voltage scales
  • 10 types of one-button shortcuts, supports Auto Setup, Default, Cursors, Measure, Roll, History, Display/Persist, Clear Sweep, Zoom and Print
  • Segmented acquisition (Sequence) mode, dividing the maximum record length into multiple segments (up to 80,000), according to trigger conditions set by the user, with a very small dead time segment to capture the qualifying event.
  • History waveform record (History) function, the maximum recorded waveform length is 80,000 frames
  • Automatic measurement function on 37 parameters, supports Statistics, Gating measurement, Math measurement, History measurement and Ref measurement
  • Math function (FFT, addition, subtraction, multiplication, division, integration, differential, square root)
  • High Speed hardware based Pass/ Fail function
  • 16 Digital channels (MSO), Maximum waveform capture rate up to 500 MSa/s, Record length up to 14 Mpts/CH (Option for SDS1000X+ models)
  • 25 MHz DDS arbitrary waveform generator, built-in 10 kinds of waveforms (Standard for SDS1000X+ models)
  • Large 8 inch TFT-LCD display with 800 * 480 resolution
  • Multiple interface types: USB Host, USB Device (USB-TMC), LAN (VXI-11), Pass / Fail, Trigger Out
  • Supports SCPI remote control commands
  • Supports Multi-language display and embedded online help

Need more information? Call us now 877-515-5551

Product Characteristics

8 inch TFT-LCD display and 10 one-button menus View more

8 inch TFT-LCD display and 10 one-button menus

8-inch TFT-LCD display with 800 * 480 resolution

Most commonly used functions are accessible using 10 different one-button operation keys: Auto Setup, Default, Cursor, Measure, Roll, History, Persist,Clear Sweep, Zoom, Print

16 Digital Channels/MSO (Optional for SDS1000X+) View more

16 Digital Channels/MSO (Optional for SDS1000X+)

2 analog channels plus 16 digital channels enable users to acquire and trigger on the waveforms then analyze the pattern, simultaneously with one instrument.

Waveform capture rate up to 400,000 wfms/s View more

Waveform capture rate up to 400,000 wfms/s

With a waveform capture rate of up to 400,000 wfm/s (sequence mode), the oscilloscope can easily capture the unusual or low-probability events.

256 intensity grading and color temperature display View more

256 intensity grading and color temperature display

SPO display technology provides for fast refresh rates. The resulting intensity-graded trace is brighter for more often-occurring display points and dimmer in less-often-occurring points.

The color temperature display is similar to the intensity-graded trace in function except that the trace occurrence is represented by different colors (color “temperature”) as opposed to changes in the intensity of one color. Red represents the most common occurrences or probabilities while blue is the least common points.

Record length of up to 14 Mpts View more

Record length of up to 14 Mpts

Using hardware-based Zoom technologies and record length of up to 14 Mpts, users are able to use a higher sampling rate to capture more of the signal and then quickly zoom in to focus on the area of interest.

Abundant trigger funtions View more

Abundant trigger funtions

SDS1000X/SDS1000X+ has a wealth of trigger modes, including Edge, Slope, Pulse, Video, Windows, Runt, Interval, Time out (Dropout), Pattern, IIC,SPI, UART/RS232, LIN, CAN

Serial bus decoding function (optional) View more

Serial bus decoding function (optional)

SDS1000X/SDS1000X+ displays the decoding through the events list. Bus protocol information can be quickly and intuitively displayed in table form.

History waveforms (History) mode and segmented acquisition (Sequence) View more

History waveforms (History) mode and segmented acquisition (Sequence)

Playback history waveform to observe unusual events and locate the source quickly through the cursor or measurements. Located on the keyboard panel, this function is easily enabled. Segmented memory collection will store the waveform into multiple (Up to 80,000) memory segments, each segment will store a triggered waveform and dead time information

Comprehensive statistical functions View more

Comprehensive statistical functions

Parametric statistical functions to display any parameters of the five measurements: current, average, minimum value, maximum value, and the standard deviation. The measurement count is also displayed. Up to five parameters can be measured and simultaneously analyzed. Supports Gated measurements, Math measurement, History measurement, Ref measurement.

Hardware-Based High-Speed Pass/ Fail function View more

Hardware-Based High-Speed Pass/ Fail function

The SDS1000X/SDS1000X+ utilizes a hardware-based Pass / Fail function, performing up to 40,000 Pass / Fail decisions each second. With easy to generate user-defined test templates, the SDS1000X/SDS1000X+ compares the current measured trace to the template mask trace making it suitable for long-term signal monitoring or automated production line testing.

Built-in 25 MHz function / arbitrary waveform generator (standard for SDS1000X+ models) View more

Built-in 25 MHz function / arbitrary waveform generator (standard for SDS1000X+ models)

The SDS1000X+ has a built-in 25 MHz function / arbitrary waveform generator (standard), including 10 built-in waveforms plus 4 ARBs. The arbitrary waveforms can be accessed and edited by the EasyWave PC software.

Advanced Math Function View more

Advanced Math Function

In addition to the traditional (+, -, X, /) operation, SDS1000X/SDS1000X+ oscilloscopes supports FFT, integration, differentiation, and square root operations

Complete connectivity View more

Complete connectivity

SDS1000X/SDS1000X+ supports USB Host, USB Device (USB-TMC), LAN (VXI-11), Pass/Fail and Trigger Out

Standard Accessories

  • Power Cord

    Power cord designed for use with the instrument in the country of operation. Available separately. Power cord H05VV-F 3G0.75MM2-004; GB-line power line (L = 1.5m ± 20mm) three plugs; product suffix; 0.13 square; black (Ju Yu)

  • Quick Start

    Printed Quick Start Guide (English)

  • USB Cable

    Standard USB cable. Also available separately.


Optional Accessories

  • STB-3

    Oscilloscope Demonstration Board. Provides standard (Sine, Square), pulse (PWM, Burst), and serial (I2C, SPI, UART, LIN, and CAN) outputs.

  • Passive Probe

    PB470; PP510; PP215; PP430

  • Current Probe

    CP4020; CP4050; CP4070; CP4070A; CP5030; CP5030A; CP5150; CP5500

  • SRF5030

    Four magnetic field near-field probes; Frequency range: 30MHz ~ 3GHz; resolution 25mm; distinguished within 10cm range of the magnetic field; for EMI radiation interference and the intensity detector.

  • High Voltage Probe

    Bandwidth: 40MHz; Maximum input differential voltage DC:10KV; AC(rms):7KV(sine);AC(Vpp):20KV(Pulse); attenuation ratio1:1000; Accuracy:≤3%

  • High Voltage Differential Probe

    DPB5150, DPB5150A, DPB5700, DPB5700A, DPB4080

  • SDS-1000X-16LA

    Activation license for the 16-channel MSO capability

  • SPL1016

    Logic Probe for SDS1000X+ series , 16-channel, 500 MSa/s

  • Isolated channel optional accessories(ISFE)

    Add isolated inputs to your oscilloscope using passive probes. Enables floating ground differential signal analysis. Overview: The ISFE provides isolated input capabilities to any oscilloscope. Independently developed by SIGLENT, it is designed to measure signals that do not share earth ground with the oscilloscope. It is suitable for use with SIGLENT’s full range of oscilloscope products. … Continued

  • SDS-1000X-DC

    Activation license for the IIC, SPI, UART/RS232, CAN, LIN decoding package

  • BAG-SCC

    Soft Carry Case for SDS1000CFL, SDS2000, SDS2000X, SDS1000X/X+, SSA3000X.

Support and Resources

Application Notes

How to Capture Runt Pulse With a Siglent SPO

Super Phosphor Oscilloscopes The new Super Phosphor Oscilloscope (SPO) technology supports deep memory, fast waveform refresh rate and a 256 grey scale and color temperature waveform display. The intelligent Pass / Fail function is widely used in industrial electronic detection. The technology also includes powerful intelligent triggering (window, interval, timeout, pattern, Runt). Here we will … Continued

Using EasyScope X to retrieve Average Waveform Data

Waveform averaging can be a useful method to decrease noise in a particular signal. The SIGLENT SDS series of oscilloscopes can easily collect average waveform data using EasyScope X software. NOTE: At this time, average waveform data is not able to be saved in CSV format via the front panel USB connection to a USB … Continued